Closeout of IE bulletin 80-17 : failure of 76 of 185 control rods to fully insert during a scram at a BWR

Title
Closeout of IE bulletin 80-17 : failure of 76 of 185 control rods to fully insert during a scram at a BWR / prepared by R.S. Dean, W.J. Foley, A. Hennick.
Author
Dean, R. S.
Publication
Washington, DC : Division of Operational Events Assessment, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, 1988.

Details

Additional Authors
  • Foley, W. J.
  • Hennick, A.
  • U.S. Nuclear Regulatory Commission. Office of Nuclear Reactor Regulation. Division of Operational Events Assessment.
  • Parameter, Inc.
Description
1 v. (various pagings); 28 cm.
Subject
  • Boiling water reactors > Accidents
  • Nuclear power plants > United States > Equipment and supplies > Evaluation
Note
  • "PARAMETER, Inc."
  • Distributed to depository libraries in microfiche.
  • "Date published: December 1988."
  • "NUREG/CR-5191."
  • "PARAMETER IE-173."
Type of Report (note)
  • Technical.
Call Number
READEX Microfiche Y 3.N 88:25/5191
OCLC
marcive19218999
Author
Dean, R. S.
Title
Closeout of IE bulletin 80-17 : failure of 76 of 185 control rods to fully insert during a scram at a BWR / prepared by R.S. Dean, W.J. Foley, A. Hennick.
Imprint
Washington, DC : Division of Operational Events Assessment, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, 1988.
Type Of Report
Technical. 3/24/88 - 11/18/88.
Funding
B8729.