- Additional Authors
- Description
- xiii, 84 p. : ill.; 28 cm.
- Alternative Title
- Analysis of shell rupture failure due to hypothetical elevated temperature pressurization of the Sequoyah Unit 1 steel containment building.
- Subject
- Note
- "Sandia National Laboratories."
- No longer available from the Superintendant of Documents.
- "Date published: February 1990."
- "NUREG/CR-5405."
- "SAND89-1650."
- Bibliography (note)
- Includes bibliographical references (p. 75-76).
- Type of Report (note)
- Call Number
- READEX Microfiche Y 3.N 88:25/5405
- OCLC
- marcive28267524
- Author
Miller, J. D.
- Title
Analysis of shell-rupture failure due to hypothetical elevated-temperature pressurization of the Sequoyah Unit 1 steel containment building / prepared by J.D. Miller.
- Imprint
Washington, DC : Division of Engineering, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission, 1990.
- Type Of Report
Technical.
- Bibliography
Includes bibliographical references (p. 75-76).
- Funding
A1401.
- Added Author
U.S. Nuclear Regulatory Commission. Office of Nuclear Regulatory Research. Division of Engineering.
Sandia National Laboratories.
- Gpo Item No.
1051-H-11 (MF)
- Sudoc No.
Y 3.N 88:25/5405
- Research Call Number
READEX Microfiche Y 3.N 88:25/5405